| Shipping Weight | 4.00 lb shipping weight |
| Underlying CS240 Cable Flammability Approvals | CS240 cable: EN45545-2 HL3 for internal and external installations; UN ECE R118.03 (E11*118R03/00*1306*00) |
| Connector (End 1) | TNC |
| Connector (End 2) | SMA |
| Connector Gender (End 1) | Male |
| Connector Gender (End 2) | Female |
| Cable Color | Black |
| Velocity Factor | 84% |
| Braid Resistance | Less than 16 mΩ/m |
| Cable Impedance At 1 GHz | 50 Ω ± 2 Ω at 1 GHz |
| Cable Impedance At 2 GHz | 50 Ω ± 4 Ω at 2 GHz |
| Cable Attenuation At 2 GHz | No greater than 0.38 dB/m at 2 GHz; cable only |
| Cable Shielding Specification | <−90 dB under IEC 61196-1 |
| Shielding | Double shielding: tin-plated copper braid and bonded aluminium foil |
| Braid Coverage | At least 93% |
| Braid Diameter | 4.52 mm |
| Outer Diameter | 6.10 mm (approximately 0.24 in) |
| Jacket Material | Low-smoke, flame-retardant TPE; AlphaGary Megolon S540NS |
| Dielectric Diameter | 3.81 mm |
| Dielectric Material | Foam polyethylene |
| Foil Shield Diameter | 3.94 mm |
| Inner Conductor Diameter | 1.42 mm |
| Inner Conductor Material | Solid copper |
| Cable Type | CS240 coaxial cable |
| Applications | Cellular, 4G/5G and WiFi; fixed and mobile installations |
| Cable Length | 15 m |
| Cable Length (Ft) | 49.21 ft |
| Cable Characteristic | Low-loss, double-screened RF extension cable |
| Cable Operating Temperature | −40 to +80 °C (−40 to +176 °F) |
| Minimum Bend Radius — One Time | 20 mm |
| Minimum Bend Radius — Repeated | 60 mm |
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
Match the required 15 m route and both connector interfaces: this assembly has a TNC male end and an SMA female end. Its CS240 cable has 50 Ω nominal impedance, a 6.10 mm outer diameter and specified minimum bend radii for routing.
The assembly terminates in a TNC male connector at one end and an SMA female connector at the other. Select it where the mating equipment or antenna cabling requires this specific combination of connector types and genders.
The underlying CS240 cable has attenuation no greater than 0.38 dB per metre at 2 GHz. This value describes the cable itself and excludes connector losses, so it should not be treated as a complete assembly insertion-loss specification.
The CS240 cable requires a minimum bend radius of 20 mm for a one-time bend and 60 mm for repeated bending. Its cable operating temperature range is −40 to +80 °C, and its outer diameter is 6.10 mm.