The HJ14126LP is a 14 x 12 x 6 in (356 x 305 x 152 mm) Type 4 and Type 12 mild steel junction box from the HJ Series, fitted with a lift-off cover secured by clamps. Its larger footprint gives room for terminal strips and control components on an inner panel. It is designed for use as an instrument enclosure, an electric, hydraulic or pneumatic control housing, an electrical junction box or a terminal wiring enclosure, and provides a degree of protection from falling dirt, dust, oil and water.
The body is formed from 16 gauge or 14 gauge steel and the cover from 14 gauge steel. Seams are smooth and continuously welded, with no knockouts, cutouts or holes. The lift-off cover seals against a seamless poured-in-place gasket, is secured with stainless steel clamps and stainless steel screws, and is retained with a stainless steel chain when open, so it stays with the box during service. Cover and enclosure are phosphatized and finished in ANSI 61 gray recoatable powder coating.
Per the drawing, the cover measures 14.31 x 12.31 in, the door opening is 13.30 x 11.30 in and 13.10 x 11.10 in of clear space is available on the door. Welded mounting brackets carry 0.31 in holes spaced 14.75 in vertically and 10.00 in horizontally, for an overall mounted height of 15.50 in. Internal threaded weld studs accept the optional 14R1311 inner panel (12.75 in (324 mm) x 10.88 in (276 mm)); alternative inner panel options are also available. A bonding stud is provided on the door and a grounding stud on the enclosure.
The HJ14126LP is listed to UL 508A Type 3R, 4, 12 and 13 (UL file E65324) and CSA Type 3R, 4, 12 and 13 (certificate LR21001), and complies with NEMA Type 3R, 4, 12 and 13 and IEC 60529 IP66. It is REACH and RoHS compliant, and ships in a box with a shipping weight of 17 lbs (7.71 kg).
| Enclosure Mounting | Welded mounting brackets |
| Inner Panel Mounting | Internal threaded weld studs |
| Alternative Inner Panels | Alternative inner panel options also available |
| Optional Inner Panel Width | 10.88 in (276 mm) |
| Optional Inner Panel Height | 12.75 in (324 mm) |
| Optional Inner Panel Part No. | 14R1311 |
| Mounting Hole Spacing, Vertical (Drawing) | 14.75 in |
| Mounting Hole Spacing, Horizontal (Drawing) | 10.00 in |
| Series | HJ Series |
| Cover Style | Lift-Off Cover with Clamps |
| Product Type | Type 4, 12 Mild Steel Junction Box |
| Long Description | N4,12 J Box Lift Off - 14x12x6 - Steel/Gray |
| Short Description | N4 J BOX LIFT OFF - 14X12X6 |
| Enclosure Depth | 6.00 in (152 mm) |
| Enclosure Width | 12.00 in (305 mm) |
| Enclosure Height | 14.00 in (356 mm) |
| Size (H X W X D) | 14 in x 12 in x 6 in (356 mm x 305 mm x 152 mm) |
| Door Size (H X W, Drawing) | 14.31 in x 12.31 in |
| Door Opening (H X W, Drawing) | 13.30 in x 11.30 in |
| Depth Including Door (Drawing) | 6.18 in |
| Clear Space Available On Door (H X W, Drawing) | 13.10 in x 11.10 in |
| Overall Height Including Mounting Brackets (Drawing) | 15.50 in |
| Series Accessories | Additional Inner Panels, Terminal Kit Assemblies, Swing Panel Kit, Door Clamping Hardware, Climate Control, General Accessories |
| UPC | 623980879352 |
| UNSPSC | 39121324 |
| Part Number | HJ14126LP |
| Packaging Type | Box |
| Shipping Weight | 17 lbs (7.71 kg) |
| Body | 16 or 14 gauge steel |
| Cover | 14 gauge steel |
| Seams | Smooth, continuously welded; no knockouts, cutouts or holes |
| Colour | Gray |
| Finish | Phosphatized, ANSI 61 gray recoatable powder coating |
| Gasket | Seamless poured-in-place |
| Material | Mild steel |
| Grounding | Bonding stud on door; grounding stud on the enclosure |
| Cover Closure | Stainless steel clamps and stainless steel screws |
| Cover Retention | Stainless steel chain when open |
| IP Rating | IP66 (IEC 60529) |
| Protection | A degree of protection from falling dirt, dust, oil and water |
| Enclosure Type Ratings | Type 3R, 4, 12 and 13 |
| UL | UL 508A Type 3R, 4, 12 and 13 |
| CSA | CSA Type 3R, 4, 12 and 13 |
| NEMA | Complies with NEMA Type 3R, 4, 12 and 13 |
| UL File # | E65324 |
| CSA Cert. # | LR21001 |
| RoHS Compliant | Yes |
| REACH Compliant | Yes |
| Applicable Standards | EN 60204-1: 2006 / IEC 60204-1: 2005-10; EN 60529: 1992 + A2: 2013 / IEC 60529: 2001-02 + A2: 2013-08 |
| Additional Declarations | RoHS Directive 2011/65/EU; Directive (EU) 2015/863 |
| EU Declaration Of Conformity | Low Voltage Directive 2014/35/EU |
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
It is listed to UL 508A Type 3R, 4, 12 and 13 (UL file E65324) and CSA Type 3R, 4, 12 and 13 (certificate LR21001), and complies with NEMA Type 3R, 4, 12 and 13 and IEC 60529 IP66.
The enclosure is 14 in H x 12 in W x 6 in D (356 x 305 x 152 mm). The drawing shows a 13.30 x 11.30 in door opening, a 14.31 x 12.31 in door and 13.10 x 11.10 in of clear space available on the door.
Yes, optionally. The series ordering table lists part 14R1311 for the HJ14126LP, measuring 12.75 in (324 mm) high by 10.88 in (276 mm) wide. It mounts on the internal threaded weld studs, and alternative inner panel options are also available.
The lift-off cover is secured with stainless steel clamps and stainless steel screws and is retained with a stainless steel chain when open.
No. The seams are smooth and continuously welded, without knockouts, cutouts or holes.
Hammond Manufacturing · 1413BGS

Hammond Manufacturing · 1413BKLGS

Hammond Manufacturing · 1413BKS
Hammond Manufacturing · 1413BNS

Hammond Manufacturing · 1413CGRALS