Exclusive pricing and Net-30 terms. Sign in or create a free account.
Create Free Business Account| Power Supply Configurations | 150 W or 250 W power supply configuration |
| 150 W Output Rating At 12 VDC | 12 A at 12 VDC |
| 150 W Output Rating At 24 VDC | 6 A at 24 VDC |
| 250 W Output Rating At 12 VDC | 20 A at 12 VDC |
| 250 W Output Rating At 24 VDC | 10 A at 24 VDC |
| Shipping Weight | 71.350 lb shipping weight |
| Output Count | 24 DC auxiliary outputs |
| Bus Selection | Each output selectable for Bus 1 or Bus 2 |
| Output Rating | 2.5 A per output |
| Power Classification | Class 2 power-limited outputs |
| Output Count | 16 relay lock-control outputs |
| Output Fuse Rating | 3 A fused per output |
| Output Configuration | Each output selectable for fire alarm interface, fail-safe, or fail-secure operation |
| Backplate | Mercury backplate |
| Door Capacity | 16-door configuration |
| Enclosure Size | E8 enclosure, 36 inches H x 30 inches W x 4.5 inches D |
| Cable Management | Panduit cable-management hardware |
| Controller Boards | Mercury MR52 / EP1502 board(s) |
Business account holders get access to exclusive pricing, volume discounts, and dedicated support. Create a free account to get started.
The specified configuration includes an E8 enclosure with a Mercury backplate and Panduit hardware, 16 fused relay lock-control outputs, 24 Class 2 auxiliary DC outputs, and Mercury MR52 / EP1502 board(s). It is configured for 16 controlled doors.
FPO150/250 names the LifeSafety Power power-enclosure platform. FPO150/250-2C83D8PE8M1/P16-A is the full ordering code for the configured 16-door version, specifying its output arrangement, E8 enclosure, Mercury backplate, Panduit hardware, and controller-board configuration.
This configuration has 16 relay lock-control outputs, each fused at 3 A. Each output can be set independently for fire alarm interface operation and for fail-safe or fail-secure locking behavior, supporting different door hardware requirements within the same cabinet.
The enclosure provides 24 Class 2 power-limited DC auxiliary outputs rated at 2.5 A per output. Each auxiliary output can be assigned to Bus 1 or Bus 2, allowing connected access-control devices to be separated across two DC distribution paths.
LifeSafety Power · FPO150-B150C8D8PE4M1
LifeSafety Power · FPO150-B100C8D8PE6M/P8-A
LifeSafety Power · FPO150-B100C82D8PE6M/P8-A
LifeSafety Power · FPO150/250-2D8P2M8PNLCE8M2/P16-A
LifeSafety Power · FPO150/250-3D8P2M8NLCE8M1/P16-A